12-36kv Porcelain Expulsion Fuse Cutout

Product Details
Customization: Available
Breaking Capacity: High
Type: Current Fuse
Manufacturer/Factory & Trading Company
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (29)
  • 12-36kv Porcelain Expulsion Fuse Cutout
  • 12-36kv Porcelain Expulsion Fuse Cutout
  • 12-36kv Porcelain Expulsion Fuse Cutout
  • 12-36kv Porcelain Expulsion Fuse Cutout
  • 12-36kv Porcelain Expulsion Fuse Cutout
  • 12-36kv Porcelain Expulsion Fuse Cutout
Find Similar Products
  • Overview
  • Standards
Overview

Basic Info.

Model NO.
RW11-12kv
Usage
High Voltage
Shape
Circle
Fusing Speed
F
Fusing Device
Pop-up Solid
Standard
Ios999
Place of Origin
Zhejiang China
Max. Operation Voltage
12kv
Rated Continuous Operation Current
200A
Rated AC Withstand Voltage
65ka
Transport Package
Each in a Plastic Bag
Specification
CE
Trademark
XIKAI
Origin
Zhejiang China
HS Code
853610000
Production Capacity
50, 000 PCS/Year

Product Description

 

12-36kv Porcelain Expulsion Fuse CutoutApplication:
This load break switch is designed for general-purpose switching on overhead main lines and branches in 11kV and 33kV systems. It is ideal for sectionalizing, ensuring reliable operation and maintenance of power distribution networks. Outdoor Pole-Mounted Three-Phase Three-Pole Load Break Switch with Ground-Level Operating Mechanism

Usual Service Conditions:
Suitable for outdoor installation with galvanized steel enclosure.
Designed to operate under varying load, voltage, and short circuit conditions within assigned ratings.
Capable of withstanding accidental short circuits.
Compatible with climatic conditions prevailing at the site.


Advantages:
Ground-Level Operation: Easy and safe operation from ground level using a standard operating stick.
Spring-Assisted Mechanism: Independent operation speed,.
Lockable Mechanism: Secure locking in both "ON" and "OFF" positions.
Visible Indicators: Clear mechanical indicators for switch status, visible from a distance of eight meters.
Durability: Designed for continuous, satisfactory operation with a long service life.
Safety: Ensures safety for operation and maintenance personnel.


Additional Features:
Galvanized Steel Enclosure: Provides robust protection against environmental elements.
Earthing Point: Facilitates easy connection of earthing cable.
Compliance: Meets IEC 60265-1 and IEC 60129 standards.
Mechanical and Electro-Dynamic Force Resistance: Maintains reliability and current carrying capacity under mechanical and electro-dynamic forces.
Technical Performance:
Load Type: Gang operated with an operating handle.
Rated Normal Current: 400 Amp for 11kV and 600 Amp for 33kV.
System Data for 11kV:
Nominal Voltage: 11000 Volt
Highest System Voltage: 12000 Volt
Frequency: 50 Hz
Short Circuit Level: 25 kA r.m.s at 11kV
System: 3-Phase, 3 wires with neutral earthed through an earthing resistance of 21.1 ohm, limiting earth fault current to 300 Amps.
System Data for 33kV:
Nominal Voltage: 33000 Volt
Highest System Voltage: 36000 Volt
Frequency: 50 Hz
Short Circuit Level: 25 kA r.m.s at 33kV
System: 3-Phase, 3 wires with neutral grounding transformer to limit the earth fault current to 1000 Amps.
Type Designation: [Specific type designation based on model and specifications]
This comprehensive product description highlights the key features, applications, and technical performance of the outdoor pole-mounted three-phase three-pole load break switch, making it clear and appealing to potential customers.

 

item
33 KV
11 KV
Nominal voltage
33000 Volt
11000 volt
Highest system voltage
36000 Volt
12000 volt
Frequency
50Hz
50 Hz
Short-circuit current (1 sec)
25KA
25 KA
Rated max continuous current
600A /630A
400A
Max overload breaking current
800A
800A
Basic impulse withstand voltage level (BIL)
175 Kv
92KV
operating system and installation
The installation heights of the switch will be about 9 meter & the operating handle about 1.8
meter above ground level. There has provision for locking the handle by padlock to be included
in the scope of supply in (on) & (off) positions. The operating mechanism is so constructed that
they cannot come of their open or closed positions by gravity ,wind pressure ,vibrations, reasonable
shocks or accidental touching of the connecting rods.
 
The bushings of the switch are made of porcelain & the base of each phase pole should be separate with
suitable insulated , inside and outside .
 
The enclosure of the switch provides the earthing terminals which is suitable for the copper wire
size(35-70mm2)
 
Breaking capacity (as minimum)
  • Mainly active load current : 100 operating cycles
  • Transformer off load current : 200 operating cycles
  • Line charging current: 200 operating cycles
  • Cable charging current : 200 operating cycles
10. Mechanical endurance : 1000 operating cycles as minimum
Standards
  • IEC62271-103 (Latest edition): High Voltage Switches for rated voltage above 1KV less than 52 KV
  • IEC62271-102 (Latest edition): High voltage switchgear & control gear part-102: A.C. disconnectors and earthing switches
  • IEC60060-1 (Latest Edition): High voltage testing technique
  • IEC62271-200 (Latest applicable): AC Metal-enclosed switchgear and control gear for rated voltage above 1KV and upto and including 52KV
  • IEC62271-1 (Latest applicable): Common specifications for high voltage switchgear and control gear standards
  • IEC60529 (Latest Applicable): Degrees of protection provided by enclosures (IP code)
 
12-36kv Porcelain Expulsion Fuse Cutout12-36kv Porcelain Expulsion Fuse Cutout12-36kv Porcelain Expulsion Fuse Cutout12-36kv Porcelain Expulsion Fuse Cutout12-36kv Porcelain Expulsion Fuse Cutout