33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A

Product Details
Customization: Available
Breaking Capacity: Lbs
Operation: Manual Type
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
35
Year of Establishment
1995-08-10
  • 33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A
  • 33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A
  • 33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A
  • 33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A
  • 33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A
  • 33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A
Find Similar Products
  • Overview
  • Corporate Profile
  • Related Products
Overview

Basic Info.

Model NO.
LBS
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Vacuum
Installation
Open Frame
Structure
ACB
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000
Modelnumber
Brfln36-36kv
Packaging Details
Wooden Package
Frequency
50/60Hz
Rated Current
630A
Supply Ability
2000 Set/Sets Per Month
Rated Voltage
33kv, 35kv36kv
Transport Package
Wooden Package
Specification
0.5
Trademark
XIKAI
Origin
Zhejiang, China
Production Capacity
2000 Set/Sets Per Month

Product Description

33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630ABRFLN36-36an indoor high-voltage SF6 load switch, an switchgear with the rated voltage of 36kV/40.5kV, adopted with SF6 gas as an arc-extinguishing and insulation medium, including the three contactors for switching-on and switching-off and to-ground, and is characteristic in its small volume, its convenient installation and operation and its the great adaptability with surroundings.

BRFLN36-36 of an indoor high-voltage SF6 load switch and BRFLN36-36D of SF6 load switch plus fuse combination can function to protect and control the electric equipments for power supply and transformer substations especially being suitable for ring net cabinet, cable branch cabinet and distribution switching substation.

BRFLN36-36 of an indoor high-voltage SF6 load switch and BRFLN36-36D load switch plus fuse combination are complied with the standards of  IEC60265-1-1998,  IEC60420 etc.

♦Service environment

a) Air temperature

Maximum temperature: +40°C; Minimum temperature:-5°C

b) Humidity

Monthly average humidity 95%; Daily average humidity 90% .

c) Altitude above sea level

Maximum installation altitude: 2500m

d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.

e) No frequent violent shake

♦Main technical specifications

No

Item

Unit

Parameter

1

Rated voltage

kV

36

2

Rated frequency

Hz

50/60

3

Rated current

A

630

4

1min Power frequency

withstand voltage

wet

kV

95

 

 

dry

kV

110

5

Lightning impulse withstand voltage

kV

185/215

6

Rated short circuit breaking current (peak)

kA

50

7

Rated active load and close circuit breaking

current

A

50

8

Rated transferring current

A

1250

9

Rated short circuit making current (peak)

kA

50

10

Rated cable(line) charging breaking current

A

50 and 10

11

Cable charge breaking current in earthing fault

A

20

12

Rated withstand current (peak)

kA

50

13

Short time withstand current (2s)

kA

20

14

Mechanism life

times

2000

Note: For short circuit breaking and peak current is based on Fuse plus combination.

 

Outline dimension & installation sizes

Matching dimension of SF6 load break switch-fuse combination Fig 1) SF6 load break switch without upper cubicle.

33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A

                                       Dimension view of load break switch

Fig 2) Whole Load break switch outline

33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A

♦Primary circuit loop of load break switch

Primary loop of BRFLN36-36 indoor load break switch and its combination is sealed in a epikote casted insulate unit by APG technology, this insulate unit has features of good insulating property, dust and dirts proof, insulate unit contains upper and lower insulate covers, inside charged 1.5bars pressure SF6 gas, the partial siding of lower cover is very thin, it's a protective measure and will burst out in the malfunction, the over pressed gas is released to protect the equipment.

SF6 load break switch and its fuse combination has open,close and earth three working position.

33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A

Arc extinction

BRFLN36-36 load break switch adopts SF6 gas as the medium of arc extinction, when switch on and off, arc occurs and will spin under the magnetic field effect ion by the permanent magnet, cooled by the SF6 gas and extricated finally.

This indoor SF6 load break switch and its fuse combination works with spring type operating mechanisms A and K, BRFLN36-36 load break switch equipped with the K spring operating mechanism is applied as the incoming control unit, while that equipped with A mechanism is applied as the outgoing protective unit and transformer unit.

 

1) "K" Type Spring Operating Mechanism

Working principle of K type spring operating mechanism is spring press and release( see fig 1. it's in off position)

A) Earthing operation

Driven by the handle, upper crank arm 4 rotates and presses spring 2 to store energy, when the max energy reached continue rotate the crank arm, the energy storage spring starts to release energy and drive the upper trigger, enables the connecting bar to drive the crank arm, crank arm rotates and drives the moving contactor for earthing.

B) Switch on operation

Driven by the handle, lower crank arm 1 rotates, presses spring 2 to store energy, when the energy released, it drives the trigger 8,enables connecting bar to drive the crank arm, crank arm rotates and drives the moving contactor and load break switch turns on.

C) Switch off operation

Rotate the main shaft crank arm counterclockwise by the handle, release the energy storage spring and the load break switch turns off.

2) "A" Type Spring Mechanism

Working principle of A type mechanism is same as K type, in addition, it has fuse striker unbuckle function. For A type mechanism, electromagnetic unbuckle is also available on customers requirement.(see fig 2)

Switch on operation.

 

A) Switch on operation
Driven by the handle, lower crank arm 1 rotates to presse switch on spring 12 and switch off spring 8 at the same time, to provide sufficient energy required by switching off. when the lower crank arm 1 buckles the pin and drives trigger to move, it makes the lower roller wheel unbuckled, and release the switch on spring and load break switch turns on.

A) Switch off operation

Press the switch off button or push the unbuckle pin 2 by the fuse striker, release the spring and load switch turns off.

B) Earthing operation

Earthing operation of A type mechanism is same as that of K type.

B) Earthing operation

Earthing operation of A type mechanism is same as that of K type.

3) K type and A type operating mechanism can be operated manually or motorized on request.

♦Notice: only when the load break turns off, can turning on and earthing operation be done.

33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A

 

Operating Mechanism & Interlock

Mechanism interlock

BRFLN36-36 indoor type medium voltage SF6 load break switch and its fuse combination has below interlocks: 

A) When load break switch turns on, earthing operation can't be done

B) When earthing switch turns on, load break switch turns on/off operation can't be done

C) Interlock outlet of mishandling pretension is equipped.

33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A

 

Installation, Maintenance & Service. 

♦Installation, Adjustment 

BRFLN36-36 type load break switch has been strictly tested before outgoing from the factory, and fully meet the technical standards, must carefully read the installation manual and prepare as below before the installation and adjustment.

Check the external appearance, any damage product is not allowed to use.

Clean the equipment and get rid of the dust and dirt may caused by the transportation or other causes.

After installation, be sure the load break switch is turned off, insert the handle to the earthing operating hole in the up part of operating panel, rotate the handle clockwise in 180o to earth the switch, rotate counterclockwise in 180o to switch off the earth.

For switching on, turns off the load break switch firstly, insert the handle to the load break switch operating hole in the lower part of panel and turn on the load switch.

From the switch on to switch off, for K type mechanism, insert the handle to the load switch operating hole and rotate it in 180o to switch off; for A type mechanism, press the "switch off" button to switch off the load break switch, observe from the winder to confirm it, check whether the on/off indication plate works properly.

Notice: only when the load break turns off, can turning on and earthing operation be done! 

Maintenance & Service

On condition of installing in environment as this manual required and normal operations, product guaranteed to be fault free for 10 years and has a running life of 25 years, but regular check per 6 months is required.

 

Keep the external appearance away from dust ,dirt and damp.

Lubricate and operate the mechanism for 3-5 times, check whether it acts properly.

Check with the pressure meter regularly, in case of meter data lower than 0.01MPa, should reload gas.

When the malfunction happens in the load break switch and fuse combination, and one of the three phase immediately, gas charging should be done by professional personnel from or trained by the manufacturer. uses burns out, all three fuses should be replaced at one time, must earth the switch before the replacement. 

Matters need attention

It is NOT allowed to disassembly the self-sealed valve in front of switch( connecting end of meter).

It is NOT allowed to unload the seal screws on switch at any time.

 

Ordering Instructions 

1. Belowing terms should be marked while ordering: Model number, product name and quantity.

Model of operating mechanism ( A,K ).

Provide the rated voltage specification if motorization operating is required.

For load break switch + fuse combination, fuse model and specification is required.

Other special requirements.

 

2. Documents with product from manufacturer: Certificate of qualification.

Testing report for products.

Packing list.

Other technical documents.

33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A    33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A

 

Corporate Profile

33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A

Related Products
33kv 35kv 36kv Sf6 Gas Jnsulated Load Break Switch Lbs 630A

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier