Customization: | Available |
---|---|
Type: | Fuse Switch Disconnector |
Structure: | Three-column Disconnector |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
GW4-126D double-column horizontal outdoor AC high-voltage disconnector is suitable for power systems with an AC frequency of 50Hz and a rated voltage of 110kV. It is used for switching high-voltage lines under no-load conditions, as well as for electrically isolating electrical equipment such as high-voltage busbars and circuit breakers under maintenance from energized high-voltage lines, providing a visible insulation distance that meets the requirements for the equipment under maintenance and maintenance personnel.
1. Double-column horizontal rotary structure;
2. Simple structure, easy debugging, beautiful appearance;
3. The isolating switch can be used in single pole, or in three-pole linkage through interphase connecting rod;
4. It has two operation modes: electric and manual;
5. It has mechanical and electrical double interlocking;
6. Most parts are made of aluminum alloy, and special anti-corrosion treatment is adopted, with strong outdoor corrosion resistance;
7. The conductive contact parts are silver-plated, and the silver-plated surface is dipped in antioxidant to prevent the switch from oxidation.
GW4 Type serial High Voltage Outdoor isolator /Disconnector /disconnecting switches comply with requirements in GB1985-2004 High-voltage Allemating Disconnecting Switches and Earthing Switches,IEC62271-102:2002AC Disconnecting Switches and Earthing Switches ,and IEC60694:1996 Common Clause for High voltage Switchgear and Control Devices.
Ambient Condition:
• Altitude:≤1000-3000m
•Ambient temperature:no more than 40°C and no less than -30°C(no less than -40°C in alpina areas )
•Wind speed:≤34m/s
•Earthquake intensity:≤8 degree
•Air pollution :IV
•Ice thickness:≤100mm
•the installation location shall be free from flammable ,explosive dangerous articies,chemical corrosion and flerce vibration
•The pollution grade of post insulator :o for general type and 2 for pollution resistance type.
Type | GW4-40.5 | GW4-72.5 | GW4-126 | GW4-126G | GW4-145 | |
Rated voltage kV | 40.5 | 72.5 | 126 | 126 | 145 | |
Rated current A |
630 1250 2000 2500 |
630 1250 2000 2500 |
630 1250 2000 2500 |
630 1250 |
1250 2000 2500 |
|
Short time withstand current ( rms) kA |
20 31.5 40(46) |
20 31.5 40(46) |
20 31.5 40(46) |
20 31.5 |
20 31.5 40(46) |
|
Peak withstand current ( peak ) kA |
50 80 100(104) |
50 80 100(104) |
50 80 100(104) |
50 80 |
50 80 100(104) |
|
Rated short-time power frequence withstand voltage ( rms ) kV | to each | 80 | 140 |
185 (230) |
185 | 275 |
between breaks | 110 | 160 |
210 (265) |
210 | 315 | |
Lighting impulse withstand voltage ( peak ) kV | to each | 185 | 325 |
450 (550) |
450 | 650 |
between breaks | 215 | 375 |
520 (630) |
550 | 750 | |
Horzontal force of terminal N |
550 (750) |
735-750 | 1000 | 1000 | 1500 | |
Weigh of signle pole kg | 80 | 200 | 240 | 300 | 3 |