Polymer Expulsion Fuse Cutout / Dropout Fuse (9kv-12KV)

Product Details
Customization: Available
Breaking Capacity: High
Type: Current Fuse
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
35
Year of Establishment
1995-08-10
Find Similar Products

Basic Info.

Model NO.
HRW12 -( 9kv-12KV)
Usage
High Voltage
Transport Package
Carton
Specification
HRW12- (9KV-12KV )
Trademark
XIKAI
Origin
Zhejiang Yueqing
HS Code
853510000
Production Capacity
50000 PCS/Years

Product Description

General

Polymer Expulsion Fuse Cutout and pull the load drop-out fuse is outdoor high-voltage protection of electrical. It is installed in high-voltage side of the distribution transformer or the Support Link of the distribution line as Transformers and lines short circuit, overload protection, and open, co-load current. Drop-out fuse is made by the insulating bracket and fuse tubes, static contact is installed at both ends of the insulation bracket, Moving contact installed on both ends of fuse tube, Fuse tube is composed by inner arc tube and outer phenolic paper tube or epoxy glass cloth tube. Pull load drop-out fuse can enhance flexibility auxiliary contacts and arc chute for open, co-load current.

When Polymer Expulsion Fuse Cutout in the normal operation, the fuse tube with fuse tension to form the closed position. When the system fails, the fault current blown fuse quickly, And form of arc, arc tube by the electric arc burning, Decompose large amounts of gas, formed a high pressure in the tube, and formed vertical wind along the pipeline, The arc was quickly stretch and elongated. After fuse blows, the moving contact lose tension and turned out, locking mechanism, release fuse tube, fuse tube drop, formed breaking Position. When pull the load, use insulating rod to pull the moving contact. At this point, the moving and the static contact is still contact. Continued pull the contact with the insulating rod, the auxiliary contacts are separated. The arc appear between the auxiliary contacts, and was stretch in the hood slit, the arc cover has gas, when the current is 0, the arc goes out.

Use and Standards

This product is used in 10 ~ 35KV distribution lines branching lines and distribution transformers primary side, For overload and short circuit protection Separation and Combination the rated load current.

The product model by JB/T8321-1996Method of type AC high-voltage fuses prepared. Product parameters made by GB15166.3-1994 high voltage fuses Expulsion fusesstandards. The standards are not clearly defined the important parameters and configuration, According to JB/DQ2139-198610 ~ 35KV outdoor high voltage drop fuse interim technology requires correction.

Conditions of Use

Ambient temperature: Not higher than +40 degree, not less than -30 degree

Altitude: Not exceed 1000m (1000m above can be corrected GB311.1-1997)

Power frequency: 50 ± 2Hz

Earthquake intensity: 7 degrees below

Maximum wind speed: 35m/s

Technical Parameters

9KV-12KV