3-Pole Mounted Outdoor 3 Phase 22kv 33kv36kv Automatic Circuit Reclosers ACR

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
35
Year of Establishment
1995-08-10
  • 3-Pole Mounted Outdoor 3 Phase 22kv 33kv36kv Automatic Circuit Reclosers ACR
  • 3-Pole Mounted Outdoor 3 Phase 22kv 33kv36kv Automatic Circuit Reclosers ACR
  • 3-Pole Mounted Outdoor 3 Phase 22kv 33kv36kv Automatic Circuit Reclosers ACR
  • 3-Pole Mounted Outdoor 3 Phase 22kv 33kv36kv Automatic Circuit Reclosers ACR
  • 3-Pole Mounted Outdoor 3 Phase 22kv 33kv36kv Automatic Circuit Reclosers ACR
  • 3-Pole Mounted Outdoor 3 Phase 22kv 33kv36kv Automatic Circuit Reclosers ACR
Find Similar Products
  • Overview
  • Product Description
  • Related Products
Overview

Basic Info.

Model NO.
BRZW32-40.5
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Oil-immersed Type
Installation
Fixed
Structure
MCCB
Poles Number
3
Type
Vacuum
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000
Selling Units
Single Item
Keyword
Pole Mounted Recloser
Single Gross Weight
100.000 Kg
OEM
Offered
Frequency
50/60Hz
Single Package Size
100X100X100.Cm
Rated Current
O
Rated Voltage
High
Transport Package
Wooden Box
Specification
0.5
Trademark
XIKAI
Origin
Zhejiang, China

Product Description

H-Pole Mounted Outdoor 3 Phase 22KV 33KV 36KV Automatic Circuit Reclosers ACR

Product Description

3-Pole Mounted Outdoor 3 Phase 22kv 33kv36kv Automatic Circuit Reclosers ACR

Our 33KV /35KV/36KV automatic reclosers have rating as defined in ANSI/IEEE Standard C37.60 (I) as summarised below:
Service Conditions:
a. Temperature-up to 45°C.
b. Altitude-up to 1,000 meters.
Rated Voltage 
a. Nominal system voltage-33,000volt
b. Rated maximum voltage -40500 volts.
c. Power frequency withstand voltage-70 KV
Rated frequency - 50 Hertz 
a tolerance of ± 5 percent. Rated symmetrical making current is the same value as the
rated symmetrical interrupting current, with asymmetrical
relationships as defined in ANSI/IEEE C37.60.
Rated minimum Impulse Withstand Voltage - 170 KV.

     
     
     

 

DESIGN33KV three phase class III recloser is in accordance with the standard ANSI/IEEE C37.60.
The recloser is designed to provide self-contained 33KV circuit protection with series trip,
solenoid operation and electronic control single break contact structure and fault interruption under
vacuum. The vacuum interrupters are in accordance with ANSI/IEEE C37.85.  The recloser is accordance with ANSI/IEEE C37.85. The recloser is  designed to sense line-to-ground, line-
to-line or three-phase fault currents and interrupt all three phases of the distribution circuit
simultaneously. The recloser is equipped with a electronic type ground feature. For fault target,
Automatic Circuit recloser will be provided with an indicator for detection of fault current on
individual phase or ground. If the Electronic Control cubicle of Reclosers or Recloser itself require
an auxiliary transformer, the manufacturer must provide the same at his cost. The recloser is
provided with in-built auxiliary transformer of required rating to provide power supply to the control
panel.

 

Rated voltage, kV

33, 35 36

Max. working voltage, kV

40.5

Rated current, not less than, A

630A / 1250A

Rated breaking current, not less than, kA

20

Electrical dynamic withstand current, kA

51

Operation times

30000

Heating withstand current (during 3 seconds/this parameter must not be as 1 sec) , not less than, kA

20

Open, close reserve, not less than  

- By rated current, Close-Open action 

- By breaking current, Close-Open action

 

30000

25

Breaking own period, not more than, ms

45

Full breaking period, not more than, ms

55

Close own period, not more than, ms

60

Testing voltage of lightning impulse, kV

190

1 min testing voltage by voltage with production frequency, kV

95

Cycle of recloser

O-0.02S-C-0.1S

Max amount of close and open cycle within 1 hour, not less than

100

Ambient environmental condition performance

Dedicated to work for outdoor and cold weather

Upper limit of ambient relative moisture when air temperature is at 25°C

            100%

 

Ambient environmental min temperature,°C (It must be approved by test)

-50

Ambient environmental max temperature,°C (It must be approved by test)

+55

Environmental condition, not less than

Above 1500 m from sea altitude

Protection degree of drive external main body

IP54

Penetration length of external insulating, mm, not less than

1700

Permissible environmental wind amount when no icing-not more than

40 m/s

Permissible environmental wind amount of wire iced period (Icing wall thickness is till 20 mm), not more than

15 m/s

Related Products
3-Pole Mounted Outdoor 3 Phase 22kv 33kv36kv Automatic Circuit Reclosers ACR3-Pole Mounted Outdoor 3 Phase 22kv 33kv36kv Automatic Circuit Reclosers ACR3-Pole Mounted Outdoor 3 Phase 22kv 33kv36kv Automatic Circuit Reclosers ACR3-Pole Mounted Outdoor 3 Phase 22kv 33kv36kv Automatic Circuit Reclosers ACR3-Pole Mounted Outdoor 3 Phase 22kv 33kv36kv Automatic Circuit Reclosers ACR

 

 

 