Customization: | Available |
---|---|
Breaking Capacity: | 25ka |
Operation: | Manual Type |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
VSC medium-voltage indoor vacuum circuit breaker is applicable for three-phase AC power
system of rated voltage 7.2kV~24kV and frequency 50/60HZ,widely used in many fields such as power plant, transformer substation, petrol chemical industry, metallurgy, manufacturing industry, airport, residential area, etc., to control and protect the electric equipment, especially, It is used for the occasion that needs infrequent operation at rated current or multi-breaking short circuit current, may be mounted in the indoor air insulating switchgear like type KYN28 or KYN96, ABB type ZS series, etc. This circuit breaker is standards as GB1984-2003 AC high voltage circuit breaker,JB3855 3.6-40.5Kv indoor AC High voltage circuit breaker,DL/T403 Specification of 12-40.5Kv indoor High voltage vacuum circuit breaker for order as well as IEC60694. This circuit breaker is made with mature APG technology. The application of VSC terminal buffer guarantees the indoor terminal is ever more reliable in nay operation environment. VSC can fully meet the requirement of GB, DL, IEC, DIN, VDE as well as standards of other advanced industrial countries.
Service environment
a) Air temperature: Maximum temperature: +40 ; Minimum temperature:-25
No. | Item | Unit | Technical Parameter | ||
1 | rated voltage | KV | 7.2, 11, 12 , 13.8 | 17.5 , 24 | |
2 | Rated frequency | HZ | 50, 60 | 50, 60 | |
3 | Rated current | A | 630,800, 1000,1250, 1600 | 630,800, 1000,1250, 1600 | |
4 |
1min Power
frequency
withstand voltage
|
wet | KV | 38 | 50 |
dry | KV | 48 | 60 | ||
5 | Brand | XIKAI | XIKAI | ||
6 | Type | side mounted | side mounted | ||
7 | rated lightning impulse withstand voltage | KV | 75 | 125 /150 | |
8 | Rated short circuit breaking current (Peak) | KA | 63, 80, 100 | ||
9 | Rated active load and close circuit breaking current | A | 63 | 50 | |
10 | Rated short circuit breaking current | KA | 20 , 25 , 31.5 | ||
11 | Rated short circuit making current (peak) | KA | 63, 80, 100 | ||
12 |
Rated cable(line) charging breaking current
|
A | 50, 100 | 50, 100 | |
13 |
Cable charge breaking current in earthing fault
|
A | 20 | 20 | |
14 |
Rated withstand current (peak)
|
KA | 63, 80, 100 | ||
15 |
Short time withstand current (4s)
|
KA | 31.5 | 31.5 | |
16 | Mechanism life | times | 10000 | 10000 |
1. 12kV, 17.5kV Indoor Vacuum Circuit Breaker (Lateral Fixed Type)
2. 24kV Indoor Vacuum Circuit Breaker (Lateral Fixed Type)